About FOAMETIX®

What is FOAMETIX®?
FOAMETIX® is a series of spray-applied polyurethane foam insulation systems designed for residential, commercial and industrial building applications. The liquid polyurethane is sprayed onto surfaces and immediately expands to form an airtight insulation barrier. FOAMETIX® offers numerous quality insulation, roofing, and sound absorption systems depending upon your personal needs and budget: FX 050, FX 100, FX 200, FX 245.
Why choose FOAMETIX®?
FOAMETIX® insulation systems are environmentally sound, technologically advanced spray polyurethane foams (SPFs) that create an air tight insulation barrier. FOAMETIX® superior insulation systems conserve energy, block moisture, reduce noise, and limit the influx of outdoor pollutants and allergens. All FOAMETIX® formulas are proprietary, and all products are developed at our own state of the art facility in Cartersville, GA. As an independent polyurethane manufacturer, FOAMETIX® implements strict quality controls and ensures that our products contain only the finest chemical ingredients. FOAMETIX® is energy smart insulation making your indoor living environment healthier, more comfortable, more energy efficient and more affordable.
Why is insulation important?
Insulation resists the flow of heat, keeping your home or work place cooler in the summer and warmer in the winter. A properly insulated building allows for HVAC equipment “rightsizing” which means that less money is spent on initial equipment costs, and more money is saved in the long run as your HVAC equipment does not work as hard to maintain a comfortable temperature. As energy costs continue to rise, a FOAMETIX® superior insulation system is one of the best investments you can make for your home or business.
What areas should be insulated?
Ceilings, walls, attics, floors, and around doors, windows, electrical outlets and lighting fixtures are all areas that should be insulated as they allow for the infiltration and exfiltration of air.
What is R-value?
R-value is the measurement of thermal resistance or the resistance to heat flow. Higher R-value means more insulation efficiency, but “air tightness” is just as important when choosing an insulation product.
What is the initial R-value of FOAMETIX®?
  • The R value of FX 050 is 3.4.
  • The R-value of FX 100 is 4.9
  • The R value of FX 200 is 6.1
  • The R value of FX 245 is 6.25
Is R-value the most important factor to consider when choosing an insulation product?
While R-value is an important insulation factor, there are other principles to consider when determining insulation efficiency. The more insulation you install, how and where you install the insulation, and the form of insulation you choose all impact the effectiveness of the thermal envelope. While traditional insulation products may offer products with high R-values, only a spray applied polyurethane foam offers the air tightness necessary for superior insulation.
Is FOAMETIX® mold and mildew resistant?
FOAMETIX® products do not sustain fungal or bacterial growth. FOAMETIX® repels water and creates an air tight barrier that drastically reduces moisture related problems in your home or work place.
What is the difference between closed cell and open cell foam?
FOAMETIX® offers both open and closed cell spray-applied insulation systems. Open cell foams are softer, more flexible, and more diffusible than closed cell foams. Open cell foams are excellent air barriers and are highly recommended for sound attenuation. Open cell foams are less expensive than closed cell foams due to their light densities. Closed cell foams are superior insulators and vapor barriers. Due to the light weight to strength ratio of closed cell foams, structural integrity of the building is increased. Closed cell foams exhibit higher insulation properties and greater compression strength than open cell foams.
How does SPF reduce energy use in buildings?
  • SPF provides a continuous air barrier.
  • SPF prevents moisture infiltration through air leakage.
  • SPF minimizes dew point problems and condensation.
  • SPF avoids thermal bridging.
  • SPF resists heat movement in all directions.
  • SPF provides reliable performance under varying conditions.
What is the difference between a vented and unvented attic?
Unvented (conditioned) attics use air-impermeable insulation as a barrier to prevent moisture condensation on the underside of roof decks. Vented attics minimize condensation by allowing the escape of moisture to the exterior by air flow.
If you spray the underside of a roof deck with SPF insulation, should you vent the attic?
No, the application of SPF insulation to the underside of the roof deck minimizes the potential for condensation. The SPF insulation develops a thermal and moisture gradient that avoids the development of dew point conditions in the attic. Because of this, moisture won't condense or accumulate and, therefore, does not need to be vented to the exterior.
Do you need a vapor retarder or a vapor barrier with SPF insulation?
It depends of the use of the building, the climate and the materials of construction. In normal occupancies and moderate climates, SPF insulation typically does require a vapor retarder. Extremes of climate and building use may require vapor retarders/barriers. Check with your design professional for specific recommendations and refer to SPFA technical document, AY 118, Moisture Vapor Transmission for further information.
Is SPF a good soundproofing material?
Both low and medium (2lb/cubic/ft) density SPF effectively reduce noise from outside sources by sealing cracks and gaps that allow sound to travel through the walls, floors and ceilings into the building. They are less effective against noise caused by vibration.
How long has SPF been around?
Spray polyurethane foam was first used commercially in the US in the 1960s for cold storage and industrial insulation projects. SPF roofing systems evolved from exterior applications to tanks and pipes in the late 60s to early 70s.